GE Healthcare
 
GE Healthcare Life Sciences Part of GE Healthcare
Location: Home > Quantitative Imaging > Selection by Application
Quantitative Imaging
Quantitative Imaging
Selection by Model/technique
Selection by Application

Find your Imager by Application
Quickly find a Quantitative Imager based on your Application.

Gel Documentation

ImageQuant 300
ImageQuant™ 300 is well suited for the busy laboratory imaging colored and fluorescent samples requiring documentation and analysis.





  • An affordable, high-performance, multipurpose gel documentation and image analysis system.
  • Full-featured darkroom cabinet for a complete range of lighting possibilities.
  • Wide dynamic range camera to avoid saturation problems.
  • High-resolution imaging over entire area of full-size transilluminator.
  • Upgradeable to cooled CCD system for high-sensitivity chemiluminescence.


ImageQuant 350

  • Cost-efficient, sensitive, and quantitative imaging of Western blots and other monochromatic fluorescence and colorimetric imaging applications.
  • 16-bit dynamic range minimizes the need for repeated acquisitions at multiple exposures because faint and dark bands can be accurately captured and analyzed in the same image.
  • High resolution, 1.92 megapixel camera delivers accurate quantitation of closely spaced bands in complex protein samples for gels and films up to 21 x 16 cm.
  • High sensitivity enables detection and quantitation of low-abundant proteins on a Western blot.
  • Simplified workflow eliminates the time, effort, and environmental waste of the darkroom.
  • Easy-to-use system allows rapid switching between applications such as analyzing blots or imaging gels, microplates, or culture dishes.


ImageQuant RT ECL

  • Real-time refresh rate provides ease of use and rapid image capture.
  • Combinations of lens, camera, and appropriate Amersham ECL reagents deliver outstanding chemiluminescent imaging sensitivity with fast exposure times.
  • Wide dynamic range, 16-bit cooled CCD camera ensures high sensitivity and avoids saturation of images.
  • Darkroom cabinet can be configured for all commonly used lighting options.
  • Cabinet design is flexible enough to allow for modifications if your requirements change or to take advantage of new opportunities.
  • Designed to complement GE Healthcare's comprehensive range of Western blotting solutions.

2-D/2-D DIGE analysis

Ettan™ DIGE Imager

  • High resolution imaging from a unique progressive scanning CCD; for differential protein expression using Ettan DIGE and relative quantitation Western Blotting with ECL Plex.
  • Optimized and balanced fluorescence detection in multiplexed experiments, ensures minimal experimental bias, superior sensitivity and signal-to-noise.
  • High sensitivity for imaging faint spots combined with a linear dynamic range greater than 3.5 orders of magnitude to allow accurate quantitation of low and high concentrations simultaneously.
  • Dedicated, removable sample handling cassettes for naked gels and membranes, as well as DALT and SE 600 series gel formats.
  • Very low noise from the innovative use of advanced low fluorescent materials within the optics path and sample cassette.
  • Shielded optics to minimize sample heating and fluorophor degradation during scanning.
  • Sealed environment for sample protection during the scanning of both wet and dry samples.
  • Cost- effective fluorescent imager with a wide application range and a powerful but low-cost light (excitation) source that can be easily replaced by the user.


Typhoon


  • Versatile system platform, handles gel sandwiches, agarose and polyacrylamide gels, membranes, microplates, and even microarrays.
  • Powerful excitation sources and innovative high-quality confocal optics allow for the sensitive detection of low-abundance targets.
  • Red-, green-, and blue-excitation wavelengths and a wide choice of emission filters enable imaging of an extensive variety of fluorophores.
  • Automated four-color fluorescence scanning allows multiplexing of multiple targets in the same sample ensuring accuracy of analysis, increasing throughput, and saving time.
  • Storage phosphor technology delivers high-resolution imaging and accurate quantitation of 3H, 14C, 125I, 32P, 33P, 35S, and other sources of ionizing radiation.
  • Highly sensitive optics enable direct chemiluminescent imaging without intermediate exposure to films or screens.

Western blotting | Chemifluorescence (ECL, ECL Plus, ECL Advance)
ImageQuant 350

  • Cost-efficient, sensitive, and quantitative imaging of Western blots and other monochromatic fluorescence and colorimetric imaging applications.
  • 16-bit dynamic range minimizes the need for repeated acquisitions at multiple exposures because faint and dark bands can be accurately captured and analyzed in the same image.
  • High resolution, 1.92 megapixel camera delivers accurate quantitation of closely spaced bands in complex protein samples for gels and films up to 21 x 16 cm.
  • High sensitivity enables detection and quantitation of low-abundant proteins on a Western blot.
  • Simplified workflow eliminates the time, effort, and environmental waste of the darkroom.
  • Easy-to-use system allows rapid switching between applications such as analyzing blots or imaging gels, microplates, or culture dishes.


ImageQuant RT ECL

  • Real-time refresh rate provides ease of use and rapid image capture.
  • Combinations of lens, camera, and appropriate Amersham ECL reagents deliver outstanding chemiluminescent imaging sensitivity with fast exposure times.
  • Wide dynamic range, 16-bit cooled CCD camera ensures high sensitivity and avoids saturation of images.
  • Darkroom cabinet can be configured for all commonly used lighting options.
  • Cabinet design is flexible enough to allow for modifications if your requirements change or to take advantage of new opportunities.
  • Designed to complement GE Healthcare's comprehensive range of Western blotting solutions.

Western blotting - Fluorescence (ECL Plus, ECL Plex)

Ettan™ DIGE Imager

  • High resolution imaging from a unique progressive scanning CCD; for differential protein expression using Ettan DIGE and relative quantitation Western Blotting with ECL Plex.
  • Optimized and balanced fluorescence detection in multiplexed experiments, ensures minimal experimental bias, superior sensitivity and signal-to-noise.
  • High sensitivity for imaging faint spots combined with a linear dynamic range greater than 3.5 orders of magnitude to allow accurate quantitation of low and high concentrations simultaneously.
  • Dedicated, removable sample handling cassettes for naked gels and membranes, as well as DALT and SE 600 series gel formats.
  • Very low noise from the innovative use of advanced low fluorescent materials within the optics path and sample cassette.
  • Shielded optics to minimize sample heating and fluorophor degradation during scanning.
  • Sealed environment for sample protection during the scanning of both wet and dry samples.
  • Cost- effective fluorescent imager with a wide application range and a powerful but low-cost light (excitation) source that can be easily replaced by the user.



Typhoon

  • Versatile system platform, handles gel sandwiches, agarose and polyacrylamide gels, membranes, microplates, and even microarrays.
  • Powerful excitation sources and innovative high-quality confocal optics allow for the sensitive detection of low-abundance targets.
  • Red-, green-, and blue-excitation wavelengths and a wide choice of emission filters enable imaging of an extensive variety of fluorophores.
  • Automated four-color fluorescence scanning allows multiplexing of multiple targets in the same sample ensuring accuracy of analysis, increasing throughput, and saving time.
  • Storage phosphor technology delivers high-resolution imaging and accurate quantitation of 3H, 14C, 125I, 32P, 33P, 35S, and other sources of ionizing radiation.
  • Highly sensitive optics enable direct chemiluminescent imaging without intermediate exposure to films or screens.


Storm®
  • Large format imaging systems for filmless autoradiography, fluorescence, and chemifluorescence imaging.
  • Filmless autoradiography based on proven PhosphorImager™ technology.
  • Direct red- and blue-excited fluorescence enable rapid and accurate quantitation using fluorescence- and chemifluorescence-based methods.
  • Five orders of linear dynamic range ensure accurate, publication-quality results on the first exposure.

Multiplex Fluorescence

Ettan™ DIGE Imager
  • High resolution imaging from a unique progressive scanning CCD; for differential protein expression using Ettan DIGE and relative quantitation Western Blotting with ECL Plex.
  • Optimized and balanced fluorescence detection in multiplexed experiments, ensures minimal experimental bias, superior sensitivity and signal-to-noise.
  • High sensitivity for imaging faint spots combined with a linear dynamic range greater than 3.5 orders of magnitude to allow accurate quantitation of low and high concentrations simultaneously.
  • Dedicated, removable sample handling cassettes for naked gels and membranes, as well as DALT and SE 600 series gel formats.
  • Very low noise from the innovative use of advanced low fluorescent materials within the optics path and sample cassette.
  • Shielded optics to minimize sample heating and fluorophor degradation during scanning.
  • Sealed environment for sample protection during the scanning of both wet and dry samples.
  • Cost- effective fluorescent imager with a wide application range and a powerful but low-cost light (excitation) source that can be easily replaced by the user.



Typhoon
  • Versatile system platform, handles gel sandwiches, agarose and polyacrylamide gels, membranes, microplates, and even microarrays.
  • Powerful excitation sources and innovative high-quality confocal optics allow for the sensitive detection of low-abundance targets.
  • Red-, green-, and blue-excitation wavelengths and a wide choice of emission filters enable imaging of an extensive variety of fluorophores.
  • Automated four-color fluorescence scanning allows multiplexing of multiple targets in the same sample ensuring accuracy of analysis, increasing throughput, and saving time.
  • Storage phosphor technology delivers high-resolution imaging and accurate quantitation of 3H, 14C, 125I, 32P, 33P, 35S, and other sources of ionizing radiation.
  • Highly sensitive optics enable direct chemiluminescent imaging without intermediate exposure to films or screens.

Single-Channel fluorescence

ImageQuant 350

  • Cost-efficient, sensitive, and quantitative imaging of Western blots and other monochromatic fluorescence and colorimetric imaging applications.
  • 16-bit dynamic range minimizes the need for repeated acquisitions at multiple exposures because faint and dark bands can be accurately captured and analyzed in the same image.
  • High resolution, 1.92 megapixel camera delivers accurate quantitation of closely spaced bands in complex protein samples for gels and films up to 21 x 16 cm.
  • High sensitivity enables detection and quantitation of low-abundant proteins on a Western blot.
  • Simplified workflow eliminates the time, effort, and environmental waste of the darkroom.
  • Easy-to-use system allows rapid switching between applications such as analyzing blots or imaging gels, microplates, or culture dishes.

ImageQuant RT ECL

  • Real-time refresh rate provides ease of use and rapid image capture.
  • Combinations of lens, camera, and appropriate Amersham ECL reagents deliver outstanding chemiluminescent imaging sensitivity with fast exposure times.
  • Wide dynamic range, 16-bit cooled CCD camera ensures high sensitivity and avoids saturation of images.
  • Darkroom cabinet can be configured for all commonly used lighting options.
  • Cabinet design is flexible enough to allow for modifications if your requirements change or to take advantage of new opportunities.
  • Designed to complement GE Healthcare's comprehensive range of Western blotting solutions.

Chemiluminescence

ImageQuant 350

  • Cost-efficient, sensitive, and quantitative imaging of Western blots and other monochromatic fluorescence and colorimetric imaging applications.
  • 16-bit dynamic range minimizes the need for repeated acquisitions at multiple exposures because faint and dark bands can be accurately captured and analyzed in the same image.
  • High resolution, 1.92 megapixel camera delivers accurate quantitation of closely spaced bands in complex protein samples for gels and films up to 21 x 16 cm.
  • High sensitivity enables detection and quantitation of low-abundant proteins on a Western blot.
  • Simplified workflow eliminates the time, effort, and environmental waste of the darkroom.
  • Easy-to-use system allows rapid switching between applications such as analyzing blots or imaging gels, microplates, or culture dishes.

ImageQuant RT ECL

  • Real-time refresh rate provides ease of use and rapid image capture.
  • Combinations of lens, camera, and appropriate Amersham ECL reagents deliver outstanding chemiluminescent imaging sensitivity with fast exposure times.
  • Wide dynamic range, 16-bit cooled CCD camera ensures high sensitivity and avoids saturation of images.
  • Darkroom cabinet can be configured for all commonly used lighting options.
  • Cabinet design is flexible enough to allow for modifications if your requirements change or to take advantage of new opportunities.
  • Designed to complement GE Healthcare's comprehensive range of Western blotting solutions.

Denisitometry
ImageScanner™ III
  • Highly sensitive flatbed scanner for for most common nonfluorescent densitometric applications in the life sciences, especially electrophoresis evaluation.
  • Linearity above 3.4 OD.
  • 16-bit pixel depth provides accurate quantitation.
  • Provides high sensitivity of very faint images without additional filters.

Storage phosphor imaging
Typhoon
  • Versatile system platform, handles gel sandwiches, agarose and polyacrylamide gels, membranes, microplates, and even microarrays.
  • Powerful excitation sources and innovative high-quality confocal optics allow for the sensitive detection of low-abundance targets.
  • Red-, green-, and blue-excitation wavelengths and a wide choice of emission filters enable imaging of an extensive variety of fluorophores.
  • Automated four-color fluorescence scanning allows multiplexing of multiple targets in the same sample ensuring accuracy of analysis, increasing throughput, and saving time.
  • Storage phosphor technology delivers high-resolution imaging and accurate quantitation of 3H, 14C, 125I, 32P, 33P, 35S, and other sources of ionizing radiation.
  • Highly sensitive optics enable direct chemiluminescent imaging without intermediate exposure to films or screens.


Storm®
  • Large format imaging systems for filmless autoradiography, fluorescence, and chemifluorescence imaging.
  • Filmless autoradiography based on proven PhosphorImager™ technology.
  • Direct red- and blue-excited fluorescence enable rapid and accurate quantitation using fluorescence- and chemifluorescence-based methods.
  • Five orders of linear dynamic range ensure accurate, publication-quality results on the first exposure.